说明:最全专利文库
ISO/TR TECHNICAL 5602 REPORT First edition 2021-11 Sourcesoferrorintheuseof electrochemical impedance spectroscopy forthe investigation of coatings and other materials Sources d'erreur dans I'utilisation de la spectroscopied'impedance electrochimiquepour I'étudedesrevetements et autresmateriaux Reference number IS0/TR5602:2021(E) ISO @IS0 2021 IS0/TR5602:2021(E) COPYRIGHTPROTECTEDDOCUMENT IS02021 All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may be reproduced or utilized otherwisein anyform or by any means,electronic or mechanical, includingphotocopying,or postingon the internet or an intranet, without prior written permission. Permission can be requested from either Iso at the address below or Iso's member body in the country of the requester. ISo copyright office CP 401 : Ch.de Blandonnet 8 CH-1214 Vernier,Geneva Phone: +41 22 749 01 11 Email: [email protected] Website: www.iso.org Published in Switzerland ii IS0 2021-All rights reserved IS0/TR 5602:2021(E) Contents Page Foreword V Introduction. vi 1 Scope. .1 2 Normativereferences .1 3 Terms and definitions .1 4 Error in the make-up of the measuring cell 1 4.1 Roughness ofthe surface 1 4.2 O-ring - Considerations about the precise determination of the exposed area 3 4.3 Faulty cell make-up. .7 4.3.1Opticallydetectableleaks. 7 .7 4.3.2 Opticallynon-detectablecauses 4.4 Referenceelectrodes 9 General information on the distance between the reference and working 4.4.1 electrodes. 9 4.4.2 Shielding 11 4.4.3 Airbubbleinthereferenceelectrode 11 4.4.4 Poisoning of the reference electrode. 11 4.4.5 Bleeding of the reference electrode 11 4.5 Counterelectrodes 11 4.5.1 Relative sizes 11 4.5.2 Reactive counterelectrodes. 11 4.6 Gas inclusions in the measuring cell .11 5 Faults caused by electronics incl. shielding .12 5.1 Faraday cage 12 5.2 Extended cable (without active shielding) ..15 5.3 Cablebreaks 16 5.4 Contactresistancesbetweenmetallic contacts andtheworkingelectrode/counter electrode. 17 5.5 Inductivities 18 5.6 Measurement range switching 19 5.7 Scattering signals in power supply 20 5.8 Insufficient signal-to-noise ratio 22 5.9 Influence of peripheral devices 22 6 Parameter selection,measurement rangelimits .24 6.1 Open-leadtest 24 .24 6.2 Noteondummycells-IS016773-3 6.3 Unsuitable amplitude .. 24 6.4 Insufficientfrequencyrange 26 6.5 Repetitionrateforsubsequentmeasurements 27 .28 7 Non-stationary measurement conditions 7.1 General. 28 7.2 Temperature fluctuations. 29 7.3 Electrolytic conductivity 31 7.4 Swelling 31 7.5 Drifting OCP 31 7.6 Corroding working electrode 33 7.7 Reactive counterelectrodes. 33 7.8 Gasformationatthecounterelectrode .33 Design and selection of equivalent circuit diagrams. .34 8 8.1 Constantphase element. .34 8.2 Multiplepossibilitiesfortheselectionof equivalentcircuits .35 @IS0 2021 - All rights reserved ii

.pdf文档 ISO-TR 5602 2021 Sources of error in the use of electrochemical impedance spectroscopy for the investigation of coatings and other materials

文档预览
中文文档 63 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共63页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO-TR 5602 2021 Sources of error in the use of electrochemical impedance spectroscopy for the investigation of coatings and other materials 第 1 页 ISO-TR 5602 2021 Sources of error in the use of electrochemical impedance spectroscopy for the investigation of coatings and other materials 第 2 页 ISO-TR 5602 2021 Sources of error in the use of electrochemical impedance spectroscopy for the investigation of coatings and other materials 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2025-05-10 19:37:49上传分享
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。